These cylinders have a ‘female’ valve connection.
Check that the connection is clean and undamaged. Always
use the correct size spanner and fully tighten (left
hand thread).
Connecting to a Propane cylinder 3.9kg, 6kg,
13kg, 19kg and 47kg sizes
|
Check that the valve handwheel is OFF by turning
clockwise.
Remove protective plug and leave hanging to replace later.
Inspect the bullnose connection on the regulator for damage before connecting.
Fit the connecting nut (left hand thread) to the cylinder, using the correct spanner. Note that Propane cylinder connections must be tight.
When gas is required, turn the valve handwheel anti-clockwise. |
|
Disconnecting from a Propane Cylinder 3.9kg,
6kg, 13kg, 19kg and 47kg sizes
| Turn the valve handwheel
OFF (clockwise rotation).
Except multi-cylinder installations with a changeover valve, turn off the gas tap if fitted to the appliance. Wait until the burner and pilot lights have gone out. For installations with a changeover valve, it is only necessary to turn off the empty cylinder.
NEVER REMOVE the regulator (or connecting nut) with the cylinder valve open.
Remove the Regulator (or connecting nut-left hand thread) with the correct spanner.
Replace protective plug into valve outlet. |
|
|